1/2POLE DP CONTACTORS(20A THRU 40A)
Straight-Through Wiring, Replaces 1-1.5 Pole Devices Used Primarily in Residential Central Air Conditioning
Definite Purpose Contactor FEATURES
.Replaces many type 117 contactors used by OEM's
.Universal style mouting bracket fits existing mounting holes
.Screw terminals and 1/4 quick connect terminals for easy installation.
Specifications
Temperature Range | -40°F to 150°F | ||||||
Mechanical Life(No load) | Conforms to UL and ARI Specifications | ||||||
Electrircal Life | Conforms to UL and ARI Specifications 94-388 thru 94-390 achieve 200,000 Cycles,make LRA at.5pf, break 125% of FLA at. 75pf at rated voltage,10,000 cycles make and brek LRA at.5pf rated voltage 94-394 thru 94-369 achieve 100,000 cycles, make LAR at 5pf at rated voltage 6.000 cycles make and break LEA at 5pf rated voltage | ||||||
Weight(approximate) | 9.25 oz | ||||||
Coils Frequency | 50/60HZ | ||||||
Coil Insulation | Class B(130°) | ||||||
Termination | Screw and Double 1/4 Q.C. | ||||||
Operate | 85% of nominal coil voltage; | ||||||
110% maximum safe opreate | |||||||
Duty Cycle | Continuous |
Coil data
Steveco nmuber | Volatge | Ress DC | Current | Nominal | Max. Inrush | ||
30 Amp 40Amp | AC | OHMS | MA | VA | VA | ||
C2-388 C2-394 | 24 | 16.5 | 208 | 5 | 20 | ||
C2-389 C2-395 | 120 | 420 | 42 | 5 | 20 | ||
C2-390 C2-396 | 208/240 | 1825 | 21 | 5 | 20 |
Contact Ratings
Type | Voltage | FLA | LRA | RES | |||
C2-388 thru C2-390 | 277 | 30 | 150 | 40 | |||
480 | 30 | 75 | 40 | ||||
600 | 30 | 50 | 40 | ||||
C2-384 thru C2-396 | 277 | 40 | 200 | 50 | |||
480 | 40 | 100 | 50 | ||||
600 | 40 | 80 | 50 |